SIM2 MultimediaSIM2 HT3000E.RS-232C Control SpecificationsRev. 1.0 (4 February 2008)
OrientationAction Command ResponseSet Floor-Rear BE EF 1A 0C 00 D8 4E 35 00 00 00 00 00 00 00 00 00 00 00 OK 20 XX 00Set Ceiling BE EF 1A 0C 00 14 8F
• Bytes 23 and 24 (labeled FF FF in the table above) contain the Failure Condition (if any):OK (No failure) 00 00Lamp Failure 00 01Fan Failure (Lamp C
Lamp StatusWhen then unit is On, the returned packet (27 byte long) is described in the following table:1E BE EF 10 13 00 .. .. 01 01 00 01 01 15 01 0
3 ExamplesSend the simulated ‘SWITCH ON FROM STANDBY’ Remote Control keycodeRemote Control allows Switching on from Standby via the key ‘0’.Send the c
SIM2 Multimedia S.p.A.Viale Lino Zanussi, 11 — 33170 Pordenone — ItalyTel. +39.0434383281 — Fax [email protected] USA Inc.101
ContentsContents 21 Introduction 31.1 Setting up the RS-232C Serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Execution of
1 IntroductionThis document describes how to interface the SIM2 HT3000E. projector with a Home Theater controlsystem (or a PC) over a direct serial co
1.2 Execution of the commandCommand execution time may vary from 0.1 to 2.0 seconds, depending on the operation that have beenrequested.If the project
2 CommandsIn this section, serial commands (and respective responses) are listed. Commands (and responses) are seriesof bytes (numbers holding values
Aspect Normal BE EF 02 06 00 2A F4 83 01 00 00 00 00Aspect Anamorphic BE EF 02 06 00 9D F5 84 01 00 00 00 00Aspect Letterbox BE EF 02 06 00 4C F4 85 0
ContrastAction Command ResponseIncrement BE EF 1A 0C 00 9D 5E 01 00 02 00 00 00 00 00 00 00 00 00 OK 20 XX 00Decrement BE EF 1A 0C 00 58 0F 01 00 03 0
Color Management: PrimariesAction Command ResponseSet Native BE EF 1A 0C 00 68 FE 41 00 00 00 00 00 00 00 00 00 00 00 OK 20 XX 00Set HDTV BE EF 1A 0C
GammaAction Command ResponseSet ST1 BE EF 1A 0C 00 05 CB 36 00 00 00 02 00 00 00 00 00 00 00 OK 20 XX 00Set ST2 BE EF 1A 0C 00 F6 CA 36 00 00 00 06 00